User's Manual
GSM/GPRS Module Series
M26 Hardware Design
M26_Hardware_Design Confidential / Released 63 / 80
1.
1)
Power control level PCL 5.
2.
2)
Power control level PCL 0.
3.
3)
Under the GSM850 and EGSM900 spectrum, the power of 1Rx and 4Tx has been reduced.
5.4. Current Consumption
The values of current consumption are shown as below.
Table 32: The Module Current Consumption
DATA mode, GPRS (4 Rx, 1Tx)
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
217/234
172/170
mA
mA
DATA mode, GPRS (1Rx, 4Tx)
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
458/485
3)
462/439
mA
mA
Peak supply
current (during
transmission
slot)
Maximum power control level
on GSM850 and EGSM900.
1.6
2
A
Condition
Current Consumption
Voice Call
GSM850
@power level #5 <300mA, Typical 223mA
@power level #12, Typical 83mA
@power level #19, Typical 62mA
EGSM900
@power level #5 <300mA, Typical 219mA
@power level #12, Typical 83mA
@power level #19, Typical 63mA
DCS1800
@power level #0 <250mA, Typical 153mA
@power level #7, Typical 73mA
@power level #15, Typical 60mA
PCS1900
@power level #0 <250mA, Typical 151mA
@power level #7, Typical 76mA
@power level #15, Typical 61mA
GPRS Data
NOTE