User's Manual

GSM/GPRS Module Series
M85 Hardware Design
M85_Hardware_Design Confidential / Released 12 / 88
2.2.2. FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator and
your body as well as kept minimum 20cm from radio antenna depending on the Mobile status of this
module usage. This module should NOT be installed and operating simultaneously with other radio. The
manual of the host system, which uses M85, must include RF exposure warning statement to advice user
should keep minimum 20cm from the radio antenna of M85 module depending on the Mobile status. Note:
If a portable device (such as PDA) uses M85 module, the device needs to do permissive change and SAR
testing.
The following list indicates the performance of antenna gain in certificate testing.
2.3. Key Features
The following table describes the detailed features of M85 module.
Table 1: Module Key Features
Implementation
Single supply voltage: 3.3V~4.6V
Typical supply voltage: 4.0V
Typical power consumption in SLEEP mode: 1.3 mA@ DRX=5
1.2 mA@ DRX=9
Quad-band: GSM850, EGSM900, DCS1800, PCS1900
The module can search these frequency bands automatically
The frequency bands can be set by AT command
Compliant to GSM Phase 2/2+
Small MS
Class 4 (2W) at GSM850 and EGSM900
Class 1 (1W) at DCS1800 and PCS1900
Part
Number
Frequency Range (MHz)
Peak Gain
(XZ-V)
Average
Gain(XZ-V)
VS
WR
Impedanc
e
GSM850:824894MHz
3R007
EGSM900:880960MHz
DCS1800:17101880MHz
1 dBi typ.
1 dBi typ.
2 max
50Ω
PCS1900: 18501990MHz