User's Manual

UMTS/HSPA Module Series
UG95 Hardware Design
UG95_Hardware_Design Confidential / Released 52 / 67
5.3. Operating Temperature
The operating temperature is listed in the following table.
Table 26: Operating Temperature
Parameter
Min.
Typ.
Max.
Unit
Normal Temperature
-35
25
70
ºC
Restricted Operation
1)
-40~ -35
70 ~ 85
ºC
Storage Temperature
-45
90
ºC
1)
When the module works within the temperature range, the deviations from the RF specification may
occur. For example, the frequency error or the phase error would increase.
5.4. Current Consumption
The values of current consumption are shown below.
Table 27: The Module Current Consumption
Parameter
Description
Conditions
Min.
Typ.
Max.
Unit
I
VBAT
OFF state
supply current
Power down
70
uA
WCDMA
supply current
Sleep (USB disconnected)
@DRX=6
1.98
mA
Sleep (USB disconnected)
@DRX=7
1.46
mA
Sleep (USB disconnected)
@DRX=8
1.24
mA
Sleep (USB disconnected)
@DRX=9
1.15
mA
Idle (USB disconnected) @DRX=6
12
mA
NOTE