User's Manual

UMTS/HSPA Module Series
UG95 Hardware Design
UG95_Hardware_Design Confidential / Released 23 / 67
Supply power to USB_VBUS will wake up the module.
The following figure shows the connection between the module and application processor.
USB_VBUS
USB_DP
USB_DM
AP_READY
VDD
USB_DP
USB_DM
GPIO
Module Processor
RI
EINT
Power
Switch
GPIO
GND
GND
Figure 4: USB Sleep Application without Suspend Function
In sleep mode, the module can still receive paging message, SMS, voice call and TCP/UDP data from the
network normally.
AP_READY is under development.
3.5.2. Minimum Functionality Mode
Minimum functionality mode reduces the functionality of the module to minimum level, thus minimizes the
current consumption at the same time. This mode can be set as below:
Command AT+CFUN provides the choice of the functionality levels: <fun>=0, 1, 4.
AT+CFUN=0: Minimum functionality, RF part and USIM card will be closed.
AT+CFUN=1: Full functionality (by default).
AT+CFUN=4: Disable RF function (airplane mode). All AT commands related to RF function are not
accessible.
For detailed information about command AT+CFUN, please refer to document [1].
NOTE