Specifications
GV200 @Track Air Interface Protocol
TRACGV200AN003 – 28 –
Figure 5: Wave Shape 4
AT+GTOUT=
Example:
AT+GTOUT=gv200,1,0,0,0,0,0,0,5,1,0,8,3,,,,,0005$
Parameter
Length(byte)
Range/Format
Default
Password 4 – 6 '0' – '9' 'a' – 'z' 'A' – 'Z' gv200
Output1 Status 1 0|1 0
Duration <=3
0–255(×100ms)
0
Toggle Times <=3 0 – 255 0
Output2 Status 1 0|1 0
Duration <=3 0 – 255(×100ms) 0
Toggle Times <=3 0 – 255 0
Output3 Status 1 0|1 0
Duration <=3 0 – 255(×100ms) 0
Toggle Times <=3 0 – 255 0
Output4 Status 1 0|1 0
Duration <=3 0 – 255(×100ms) 0
Toggle Times <=3 0 – 255 0
Long Operation <=3 0 – 120min 0
DOS Report 1 0 – F 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Output1
–
4 Status>: Used only for the wave shape 1 as shown in Figure 2 to set the final
status of the output port.
0: Disable status.
Queclink
Confidential