User's Manual
4. Digital I/O Connection
If the voltage level of peripheral interface circuit does not match module interface, the power
consumption of the system could increase, and could even cause the module damaged.
Each digital I/O of the module operates in a 2.8V logic level inside the module. The voltage
level of those digital interfaces connected to the module should match the electrical
characteristics of the module listed in Table 2. Otherwise, a level shifter circuit must be
inserted between the host and the module.
Table 1: Digital I/O electrical characteristics
SYMBOL
MIN
MAX
UNITS
VIL
0
0.67
V
VIH
1.7
3.1
V
VOL
0
0.34
V
VOH
2.0
2.8
V
For direct connection between I/Os, please pay attention to I/Os’ input or output configuration.
If the I/O direction configuration conflicts with each other, the power consumption could
increase, and the module could be very hot, and even be damaged. For example, it is forbidden
that user’s I/O outputs a low level while module’s connected I/O outputs a high level.