Figure5. TypicalPowerConnection
Table6. ElectricalCharacteristicsofIgnitionDetection
Logicalstatus Electricalstatus
Active
8.0Vto32V
Inactive 0Vto3Voropen
Figure6. TypicalIgnitionDetection
IGN (Pin9) is used for
ignition detection. It is strongly recommended to connect this pin to
ignitionkey“RUN”positionasshownabove.
Analternativetoconnectingtotheignitionswitchistofindanonpermanentpowersourcethat
isonlyavailablewhenthevehicleisrunning.Forexample,thepowersourcefortheFMradio.
IGN signal ca
n be configured to start transmitting information to the backend server when
ignitionisonandenterpowersavingmodewhenignitionisoff.
4.5. IgnitionDetection