FM radio.
IGN signal can be configured to start transmitting information to backend server when
ignition is on; and enter power saving mode when ignition is off.
3.5. Digital Inputs
There are one general purpose digital inputs on GV55VC. They are all negative trigger.
Table 7. Electrical Characteristics of the digital inputs
Logical State Electrical Characteristics
Active 0V to 0.8V
Inactive Open
The following diagram shows the recommended connection of a digital input.
Figure 7. Typical Digital Input Connection
3.6. Digital Outputs
There are two digital outputs on GV55VC. All are of open drain type and the maximum
drain current is 150mA. Each output has the built-in over current and recovery PTC fuse