User's Manual
GV55 User manual
TRACGV55LITEUM001 - 13 -
Table 6. Electrical Characteristics of Ignition Detection
Logical State Electrical State
Active 5.0V to 32V
Inactive 0V to 3V or Open
Figure 7. Typical Ignition Detection
IGN (Pin3)is used for ignition detection. It is strongly recommended to connect this pin to
ignition key “RUN” position as shown up.
An alternative to connecting to the ignition switch is to find a non permanent power source
that is only available when the vehicle is running. For example the power source for the
FM radio.
IGN signal can be configured to start transmitting information to back-end server when
ignition is on; and enter power saving mode when ignition is off.
There are one general purpose digital inputs on GV55. They are all negative trigger.
Table 7. Electrical Characteristics of the digital inputs
Logical State Electrical Characteristics
Active 0V to 0.8V
Inactive Open
The following diagram shows the recommended connection of a digital input.
3.5. Ignition Detection
3.6. Digital Inputs