2.5. Ignition Detection
IGN (Pin4) is used for ignition detection. It is strongly recommended to connect this pin to
ignition key “RUN” position as shown below.
An alternative to connecting to the ignition switch is to find a non-permanent power source that
is only available when the vehicle is running. For example, the power source for the FM radio.
IGN signal can be configured to start transmitting information to backend server when ignition is
on, and enter power saving mode when ignition is off.
Table 5: Electrical Characteristics of Ignition Detection
Logical State
Electrical State
Active
5.0V to 32V
Inactive
0V to 3V or Open
Figure 4: Typical Ignition Detection
OUT1/IN1 (PIN5) is a digital Output/Input connection on GV50LTA. It is of open drain type
and the maximum drain current is 150mA. The OUT1/IN1 (PIN5) can be used as a digital
Output and a (negative trigger) digital Input.
2.6. Digital Output/ Input Connection