Logical State Electrical Characteristics
Active 0V to 0.8V
Inactive Open
The following diagram shows the recommended connection of a digital input.
Figure 8. Typical Digital Input Connection
3.7. Digital Output
There is a digital output on GV35 which is open drain type and can latch the output statue
when there is no control. The output has a built-in over current and recovery PTC fuse and
the maximum drain current is 150 mA.
Figure 9. Digital Output Internal Drive Circuit