3.11. Digital Outputs
There are three digital outputs on GV300W. All are of open drain type and the maximum
drain current is 150 mA. Each output has the built-in over current PTC resettable fuse.
Figure 13. Digital Output Internal Drive Circuit
Table 9. Electrical Characteristics of Digital Outputs
Logical status
Electrical characteristics
Enable
<1.5V @150 mA
Disable
Open drain
Figure 14. Typical Connection with Relay