Specifications
If you wish to rerun the IVP, you must reboot the system exerciser or type run
to continue running SYSEX tests, but without the 15-minute (default time)
timeout.
3.9.14 Log
The log command lets you write error reports to a DOS diskette, play back
error reports that have been logged, and remove reports from the log.
Format: LOG[/error, /recovered] [<PLAY,CLEAR> entry_number, last]
or
Format: LOG ARCHIVE filename.ext
Table 3–12 describes options that can be used with the log command.
Table 3–12 Log Command Options
Command Description
L[og] Display error log summary.
L[og] archive filename.ext Write all error reports to a DOS diskette.
L[og] clear entry-number Remove specific error reports.
L[og] clear Remove all error reports.
L[og] play entry-number Play back specific error reports.
L[og] play Play back all error reports.
RUN> log
Enter
Table 3–13 illustrates a typical log summary report.
Table 3–13 System Exerciser Error Log Report, Example
Entry Error Test Log Address
0 1 9 28316
1 2 6 27FFA
2 3 15 27AB2
The Entry column denotes which entry from the error log is being described.
The Error column denotes whether this is the first, second, third, or nth
encounter of an error in the test run. The Test column denotes which of the
SYSEX tests reported the error. The Log Address column describes where the
report is logged in memory.
3–20 System Exerciser