Specifications

Table 4–17 Bay Option Installation Data
Description Model No. Jumpers Screws Connect to:
525 MB QIC tape
drive
TZK10-AA Figure 4–16 Metric SCSI bus cable
209 MB HH disk
drive
RZ24-S Figure 4–17 SAE SCSI bus cable
426 MB HH disk
drive
RZ25-S Figure 4–18
1
SAE SCSI bus cable
665 MB FH disk
drive
RZ56-E Figure 4–19 SAE SCSI bus cable
1.0 GB FH disk
drive
RZ57-E Figure 4–19
and
Figure 4–20
1
SAE SCSI bus cable
852 MB HH disk
drive
RZ35-E Figure 4–21
1
SAE SCSI bus cable
1.3 GB FH disk
drive
RZ58-E Figure 4–22
1
SAE SCSI bus cable
105 MB HH IDE
disk drive
PC4XR-EB Figure 4–23 SAE IDE bus cable
1.2 MB 5.25-inch
HH diskette drive
RX33-AS Figure 4–24
2
Metric Diskette drive cable
1
Verify that the drive is jumper configured for spin-up on power.
2
Verify that jumpers U1, D1, DC2, Density, and Grounding are installed.
Figures are listed in Table 4–17 to help you locate the drive’s ID jumpers
(and other jumpers, if applicable). Each SCSI drive has three ID jumpers
which assign its unique ID on the bus. The jumpers specify the ID in binary
format as shown in Figure 4–15. The drive IDs on the SCSI bus are assigned
according to the system configuration. Drives on the IDE bus are jumpered
according to how many drives are on the bus and, if there are two, which is the
primary and which is the secondary (Figure 4–23).
FRU Removal and Replacement 4–33