Specifications
4.10 Replacing Option Modules
The following steps describe the removal procedure for option modules. Refer
to Figure 4–10 and Table 4–12 during the procedure.
1. Shut down the system and unplug the power cord (Section 4.4).
2. Remove the cabinet top cover, left side panel, and card cage cover using the
procedure in Section 4.5.
3. Disconnect any external cables attached to the option module I/O
connections at the back of the system.
4. Disconnect any internal cables from the option module.
5. Remove the screw that secures the module. Save this screw.
6. Pull the failed option module from its slot and slide the module out of the
card cage.
7. Place the module on top of an antistatic package, antistatic foam pad, or a
grounded workstation surface.
8. Remove the replacement module from its antistatic package and place it
on an antistatic package, antistatic foam pad, or a grounded workstation
surface.
9. Ensure that the jumpers on the replacement module match the positions of
the jumpers on the failed module.
10. Place the failed memory module in an antistatic package.
Install the replacement module into the same slot from which you removed the
failed module. Reverse the above procedure to install the module.
4–20 FRU Removal and Replacement