Section 1: Installing Quatech DS-100 Card using Win 3.11
Insert the Quatech DS-100 serial adapter card into a spare ISA slot on the motherboard and
start-up the SCU.
386/486 requires no BIOS set-up of serial ports (NB: 95% of Winson SCU-3’s are 386/486).
Pentiums will require BIOS set-up in the same way as a Win 9x installation.
Installation
1. Double click Main => double click Control Panel => double click Ports.
2. Highlight COM 3 => Click on Settings.
3. Click on Advanced.
=> Change the Base I/O Port Address to 03E8.
=> Change the Interrupt Request Line (IRQ) to 5.
=> Click on OK.
4. Click on OK.
5. Highlight COM 4 => Click on Settings.
6. Click on Advanced.
=> Change the Base I/O Port Address to 02E8.
=> Change the Interrupt Request Line (IRQ) to 11.
=> Click on OK.
7. Click on OK.
Section 2: Installing Quatech DS-100 Card using Win 9x (with driver disk)
Require ISA Communication – Drivers & Utilities Version 2.0’ disk.
Insert the Quatech DS-100 serial adapter card into a spare ISA slot on the motherboard and
start-up the SCU.
Ensure that Interrupts 5 and 11 are allocated for ISA bus use in BIOS (NB: Non Plug and
Play/PCI).
Part 1: Installation
1. Start => Settings => Control Panel.
2. Double click on Add New Hardware => Click on Next => Click on Next.
3. When asked if you would like Windows to search for your new hardware, select:
=> No, select from hardware list => Click on Next.
4. Highlight Multi-function adapters => Click on Next.
5. Click on Have Disk.
6. Insert disk labelled ‘ISA Communication – Drivers & Utilities Version 2.0’ => Click on OK.
7. Highlight Quatech DS-100: 2 RS-232 Ports => Click on Next.
8. A list of Interrupts and base addresses will be shown (self-configured with default interrupt
values) => Click on Next.
9. Click on Finish.
10. When prompted, remove any disks from drives and restart the SCU.
11. The Hardware Wizard will detect an unknown device => Click on Next.
12. Select Display list of drivers => Click on Next.
13. Highlight Multi-function adapters in list => Click on Next.
14. Click on Have Disk.
15. Insert disk labelled ‘ISA Communication – Drivers & Utilities Version 2.0’ => Click on OK.
16. Quatech Serial Port [3-12-97] should be highlighted => Click on Next => Click on Next.
17. When prompted for Win 98 CD, select to copy files from D:\WIN98 => Click on OK.