Specifications
Tritech International Ltd SeaKing System Options OM
Issue 3 TIL – Eng – Spec – 040 Page 37 of 44
Configuring Seaking Comms Board for AUX Serial I/O
Step 1:
Before opening the Sonar head to access the Comms board jumpers, using the 'V3Setup' Utility
Program configure the following check box settings. These are needed to enable the 'Aux' port;
Note: “Board Rev” box may show SK5 on later
Sonar heads, this should not be changed!!
If the ‘AuxComm 1 Sec Rate’ check box is disabled, the Sonar will try to send up all data collected
through it’s auxiliary port. Please be aware that if the quantity and rate of this data is too great then
the interface may hang up.
Step 2:
The Comms board inside the SeaKing head must be a COMDV3, COMFV3 COMGV3 or COMV5
board and the jumpers should be set as follows.
Always ensure that the sonar Aux port is fitted with a Water Block connector.
NOTE When connecting an RS232 Tritech Altimeter
1) The Altimeter analogue output must be disabled by removing R1 from the power pcb.
2) Pin 4 and pin 5 on the AUX connector must be linked on the SeaKing comm. Pcb
Check the 'Has Aux or Compass'
box to enable the Aux Port.
Check the 'AuxComm 1 Sec Rate'
box to restrict only 1 message per
second processing.
NET
A
UX
JP6
JP1
JP2
RS232 ON
JP5
5V 12V
JP3
R26
(removed)
(Enable RS232 Altimeter
'AUX' port)
(RS232 Gnd Link)
DV3 / FV3 Comm boards
a) RS232 Altimeter
NET
A
UX
JP6
JP1
JP2
RS232 OFF
JP5
5V 12V
JP3
R26
(removed)
(Pin5 Altimeter Analogue
Link through)
(Enable RS485 Altimeter
'AUX' port)
DV3 / FV3 Comm boards
a) RS485 Altimeter