Specifications
Tritech International Ltd SeaKing System Options OM
Issue 3 TIL – Eng – Spec – 040 Page 21 of 44
Example: Head at XYZR=0, no time correction, 5 * 5metre ranges in microseconds, Start at 199,
Ultimate, PRFRT, Vprop = 1500, Scan Start at 15:27:33:02, Duration 33msecs, Orientation Upright,
1
st
Ping Time at 15:27:34:62, 2
nd
at 15:27:34:627, 3
rd
at 15:27:34:634, 4
th
at 15:27:34:64, 5
th
at
15:27:34:646. ASCIIText =
a) Normal
Time Mode Ping Time:
“+00000+00000+00000+00000+000000000303184+008150001527330200033016066670666706667
0666706667*01601600+01607+01614+01620+01626”
b) Delta
Time Mode Ping Times:
“+00000+00000+00000+00000+000000000303184+008150001527330200033018066670666706667
0666706667*01801600+007+007+006+006”
[N.B. Consult Tritech before changing RV4VER, default will be RV4VER=2]
* Note 1:
Controlled by RV4VER in SONV3SO.INI.
[RV4VER=0 for Normal Mode, RV4VER=2 for Delta Mode]
* Note 2:
This Mode can also be forced by setting RV4VER=16 in SONV3SO.INI. It will override Roll
Angle Output to give Ping Time Outputs in the extended part of the message.
* Note 3:
+127 and –128 are delta overflow error conditions