Specifications

Tritech International Ltd SeaKing System Options OM
Issue 3 TIL – Eng – Spec – 040 Page 11 of 44
Section 3: Installing Quatech DS-100 Card using Win 9x (without driver disk)
Insert the Quatech DS-100 serial adapter card into a spare ISA slot on the motherboard and
start-up the SCU.
Ensure that Interrupts 5 and 11 are allocated for ISA bus use in BIOS (NB: Non Plug and
Play/PCI).
Installation
1. Start => Settings => Control Panel.
2. Double click on Add New Hardware => Click on Next => Click on Next.
3. When asked if you would like Windows to search for your new hardware, select:
=> No, select from hardware list => Click on Next.
4. Highlight Ports (COM & LPT) => Click on Next.
5. Highlight (Standard port types) under Manufacturers list and highlight Communications Port
under Models list => Click on Next.
6. A list with a default Interrupt value and base address will be shown => Click on Next.
7. When prompted to restart the SCU, click on NO.
8. Start => Settings => Control Panel.
9. Double click on System.
10. Select the Device Manager tab.
11. Double click on Ports (COM & LPT).
12. Highlight Communications Port (COM3) => Click on Properties.
13. Click on the Resources tab.
14. Highlight Input/Output Range => Click on Change Setting.
NB: If you are told that the resource setting cannot be modified change the Basic Configuration
setting in the drop down list above and repeat step 14.
15. Change Value to 03E8 – 03EF => Click on OK.
16. Highlight Interrupt Request => Click on Change Setting.
17. Change Value to 05 => Click on OK.
18. Click on OK.
19. When prompted, shut down and restart the SCU.
20. Repeat steps 1 to 11.
21. Highlight Communications Port (COM4) => Click on Properties.
22. Click on the Resources tab.
23. Highlight Input/Output Range => Click on Change Setting.
NB: If you are told that the resource setting cannot be modified change the Basic Configuration
setting in the drop down list above and repeat step 23.
24. Change Value to 02E8 – 02EF => Click on OK.
25. Highlight Interrupt Request => Click on Change Setting.
26. Change Value to 11 => Click on OK.
27. Click on OK.
28. When prompted, shut down and restart the SCU.