User`s guide

Airborne Control Center
100-8006-152G AirborneDirect™ Serial Bridge User’s Guide Page 37
Quatech, Inc. Confidential
Network Connection Settings
Primary LAN Server IP
Address
Specifies the Primary IP Address of the LAN device to which the Bridge
will deliver incoming serial data, when a TCP tunnel is open. An IP
address of 0.0.0.0 will disable this function.
Default is 0.0.0.0.
Secondary LAN Server
IP Address
Specifies the Secondary IP Address of the LAN device to which the
Bridge will deliver incoming serial data, when a TCP tunnel is open. An IP
address of 0.0.0.0 will disable this function.
Default is 0.0.0.0.
LAN Server Port Port number of the LAN host to which the Bridge will connect.
Default is 2571.
TCP Session Inactivity
Timeout – seconds
Number of seconds of inactivity after which the TCP session with the LAN
host ends. A value of 0 makes the timeout infinite.
Default is 60.
Serial Default Specifies whether the serial port will initialize in LISTEN or PASS mode.
Default is LISTEN.
Connection Retry Time
– seconds
Defines the delay, in seconds, between attempts to establish a TCP
connection with a LAN TCP server.
Default is 10.
Outbound Connection
Mode
Select TCP, UDP or Both.
Default is TCP.
Enable TCP Direct
Tunnel on Specified
Tunnel Port
Enables the TCP tunnel server capability. If enabled, the Tunnel TCP
Server is accessible from a LAN application and immediately enters data
pass mode without requiring authentication.
Default is unchecked. (Disabled)
Select the Tunnel
Mode
Select TCP or UDP.
Default is TCP.
TCP Listen Port to
Tunneling
Defines the TCP port the Tunnel server will listen on for an inbound TCP
connection.
Default is 8023.