Specifications
Compact RDMS
TM
Telemetry Receiver
16 Quasonix, Inc.
Mnemonic Name Description
Option (s)
Required
Basic or
Advanced
Command
Mode
Restriction
RN
Derandomizer
State
Report or set the
derandomizer state
Examples:
RN Report the
derandomizer state
RN 0 Set the derandomizer
OFF
RN 1 Set the derandomizer
ON
Standard Basic None
SN
Show Serial
Number
Report the serial number for
the unit
Standard Basic None
SV
Save
Parameters
Saves the current
parameters in non-volatile
memory, including
frequency, modulation, bit
rate, data polarity, clock
polarity, AGC state,
verbosity level, etc.
Standard Basic None