Specifications
Compact RDMS
TM
Telemetry Receiver
9 Quasonix, Inc.
Mnemonic Name Description
Option (s)
Required
Basic or
Advanced
Command
Mode
Restriction
CP Clock Polarity
Report or set clock polarity
inversion state
Examples:
CP Report the clock
source state
CP 0 Set clock inversion
OFF
CP 1 Set clock inversion
ON
Standard Basic
For Asynch
PSK
(legacy)
modes, CP
A and CP
B must be
specified
separately
DE
Differential
Decoder
Enable
Report or set differential
decoding
Examples:
DE Report the
differential decoding
setting
DE 0 Set differential
decoding OFF
DE 1 Set differential
decoding ON
Standard Basic SOQPSK
DP Data Polarity
Report or set data polarity
inversion state
Examples:
DP Display the current
data polarity
DP 0 Set data polarity to
NOT inverted (OFF)
DP 1 Set data polarity to
inverted (ON)
Standard Basic
For Asynch
PSK
(legacy)
modes, DP
A and DP
B must be
specified
separately
FL
Force Lock
Indication
Diagnostic tool to force the
system to indicate locked or
unlocked status; primarily
used to verify wiring setup
Examples:
FL Show the force lock
state
FL 1 Force lock to ON
FL 0 Force lock to Normal
FL -1 Force lock to OFF
Standard
Advanced
Command
None