Vents for roof ventilation are often found in the
soffit. Placing vents in these locations creates a
perfect path for fire to enter the roof structure.
If the vent must be in this location it is better to
place it farther from the wall and closer to the
fascia. The vent can also be placed in the fascia
or near the lower edge of the roof.
Quarrix
Multi Roll
®
Ridge Vent
FLASHING
TRIM
TAR PAPER
STEP 1
Slot Preperation
Determine amount of ventilation required and length of slot Cut a horizontal 1” slot
in the deck right before the wall Leave 6” uncut on each end of the slot. Install
underlayment and shingles per manufacturer’s instructions.
STEP 2
End Cap Installation
Trim end cap to fit at each end of vent. Cut a slit in the StormStop membrane 1⁄2”
by the thick part of vent. Place sealant on both sides of StormStop membrane. Insert
foam end cap with the cut-back StormStop material between the end cap and the
underside of the vent. End caps must be installed at the beginning and end of each
vent section.
STEP 3
Sealant Placement
Lay a bead of sealant 3” below the cut slot. Place front edge of vent 4” below the
pre-cut slot. Unfold the membrane and pull straight. Nail membrane and plastic to roof
deck. All nails must penetrate the roof deck at least 3⁄4”. Nail down the bottom lead
edge of vent and in the middle through the end cap. Roll out vent and pull tight; nail
at 10’ and again at the end of the roll.
STEP 4
Multi Roll Multi-Purpose Vent Installation
Nail lead edge of vent into roof deck. Nail foam end cap in place. All nails must
penetrate the roof deck at least 3/4”. Roll out Multi Roll Vent and pull tight, nail at
10’ and again at the end of the roll. Tack the vent along the wall, making sure nails
penetrate plastic and StormStop membrane. Nail every 6”.
STEP 5
Finishing
Install metal flashing as counter flashing on top of vent. Install siding over the vent
piece on wall. When finished, siding should cover the wall and overlap the metal
flashing.
DO NOT COVER PRE-CUT SLOT
CAULK