User Manual

LEA-6 - Data Sheet
GPS.G6-HW-09004-E2 Page 10 of 26
1.11.3 Eco Mode
During a Cold start, a receiver in Eco Mode works exactly as in Maximum Performance Mode. Once a position
can be calculated and a sufficient number of satellites are being tracked, the acquisition engine is powered off
resulting in significant power savings. The tracking engine continuously tracks acquired satellites and acquires
other available or emerging satellites.
Note that even if the acquisition engine is powered off, satellites continue to be acquired.
1.11.4 Power Save Mode
Power Save Mode (PSM) allows a reduction in system power consumption by selectively switching parts of the
receiver on and off.
Power Save mode is not available with LEA-6R.
1.12 Configuration
1.12.1 Boot-time configuration (LEA-6A, LEA-6S)
LEA-6A and LEA-6S modules provide CFG_COM1 for boot-time configuration. This pin becomes effective
immediately after start-up. Once the module has started, the configuration settings can be modified with UBX
configuration messages. The modified settings remain effective until power-down or reset. If these settings have
been stored in battery-backup RAM, then the modified configuration will be retained, as long as the backup
battery supply is not interrupted.
UART settings can be can be configured as seen in Table 6 with the CFG_COM1 pin. Default settings in bold.
CFG_COM1 Protocol Messages UARTBaud rate
1 NMEA GSV, RMC, GSA, GGA, GLL, VTG, TXT 9600
0 NMEA GSV
10
, RMC, GSA, GGA, VTG, TXT 4800
Table 6: Supported CFG_COM1 settings (LEA-6A, LEA-6S)
1.12.2 Configuration (LEA-6H, LEA-6R, LEA-6T)
With the LEA-6H, LEA-6R LEA-6T-0 and LEA-6T-1, configuration settings modified with UBX configuration
messages can be saved permanently. In this case the modified settings remain effective even after power-down
and don’t require backup battery supply.
LEA-6T-0 includes a serial Flash memory for storage of configuration. Saving full configurations might take
several seconds to store on LEA-6T-0. Do not power down the Module before receiving the acknowledge.
For more information, see the u-blox 6 Receiver Description including Protocol Specification [2].
1.13 Design-in
In order to obtain the necessary information to conduct a proper design-in, u-blox strongly recommends
consulting the LEA-6/NEO-6/MAX-6 Hardware Integration Manual [1].
10
Every 5
th