Installation and Operating Guide
22 Equipment Description
SCSI Parity
Lets you enable or disable the reporting of SCSI parity. Press 
ENTER
 to access this
function.
Use 
UP
   or 
DOWN
   to select "Y" to enable the reporting of parity check or "N"
to disable the reporting of parity check. Press 
ENTER
 to activate the change.
Note
Off-Line Time
Lets you set the number of minutes the VLS will remain in the Off-Line mode. If
someone leaves the VLS in an Off-Line mode, after the pre-set number of minutes the
VLS will automatically return On-Line. This assures that your automatic backup will
be done even if the VLS has accidentally been left Off-Line.
Use 
UP
   or 
DOWN
   to select the number of minutes you wish the VLS to remain
Off-Line. Press 
ENTER
 to execute the change.
Note