User`s guide
Chapter 7 Troubleshooting Guide
Troubleshooting Suggestions
LTO-3 Half-Height Tape Drive User’s Guide 66
3 If the tape drive is not recognized when the SCSI controller scans for
devices, check the
Power LED on the LTO-3 Half-Height Tape Drive
front panel to make sure the drive is receiving power.
4 If the
Power LED is off, check the power connections to the tape drive.
For the internal tape drive:
a Shut down the system, remove the cover, and re-seat the DC
power cable connector on tape drive.
b Restart the system and check the
Power LED.
.
IF the tape drive is . . .
during system startup, THEN . . .
recognized the problem has been resolved.
not recognized proceed to step 3 to determine whether
the tape drive is receiving power.
IF the Power LED is . . . THEN . . .
off, proceed to step 4 to check the power
connections to the tape drive.
on, proceed to step 5 to determine whether
the drive passed the Power On Self
Test functions.