User's Manual

Chapter 5 Troubleshooting
A407: Directory Read
196 SuperLoader User’s Guide
Cause 5 This is due to the DLT needing to rebuild the directory
Suggested
Actions 5
Following is a list of suggested actions:
This information can be used to determine if the application may be
timing out due to the DLT needing to rebuild the directory or a
Space/Locate command may be taking too long.
Check to insure the previous drive that used this media did not have
an A408 Event indicating it could not write the directory successfully.
A partial directory may be the result from a drive that lost power
while the media was still loaded. Please confirm this or confirm that
the last drive to use this media did to have a directory write problem.
Perform a complete Read Only test on the media to determine if the
media is readable.
Status 3 Directory Recovery Status (EEPROM directory status used for
recovery)
01h = Recovered Directory, but pending validation
0Ah = No LBN 0
0Bh = Media ID of media and EEPROM directory do not match
0Ch = On Tape directory not empty
0Dh = Sync lock Mismatch
14h = Bugcheck during directory update
Field Description