Step 3: Prepare the Bar Code Reader
Bay
a. With the SuperLoader on a flat work surface, remove the top
cover of the SuperLoader as follows:
(1) Remove the PHILLIPS screws (SuperLoader LTO has four
screws, SuperLoader DLT
TM
has two screws) from the top
of the SuperLoader and four PHILLIPS screws from the
back.
(2) Slide the cover backwards approximately 2 inches
(5.0 cm), and then lift it off.
c. Locate the bar code reader bay directly above the picker. A
foam insert protects the electronics.
d. Pull the foam insert straight up to remove it. Then, discard
the foam insert.
e. Locate the small flex cable inside the bar code reader bay.
Gently pull up on this cable to straighten it.
Step 4: Install the Bar Code Reader
Caution: These instructions are for both the
SuperLoader DLT and the SuperLoader LTO due to the
nature of their similarities. The bar code reader is not
interchangeable. Please order the appropriate part
numbers when replacing this item.
a. Take appropriate ESD precautions including creating an
antistatic work area and wearing an antistatic wrist strap and
other antistatic apparel (smock, etc.).
b. Remove the bar code reader from its antistatic packaging.
Avoid touching the bar code reader mirror.
Caution: Touching the mirror can cause the reader to
malfunction.