User's Manual
Chapter 5 Administration
Setting Ethernet
Quantum SuperLoader 3 User’s Guide 74
5 Press Enter. New Subnet Mask xxx.xxx.xxx appears on the LCD. You
do not need to reboot the autoloader.
6 Press
Escape or Enter to return to the Ethernet submenu.
Setting an IP Gateway 5
To set an IP gateway:
1 From the main menu, scroll to
Configuration, and then press Enter.
2 From the
Configuration menu, scroll to Ethernet, and then press Enter.
3 From the
Ethernet submenu, scroll to Set Gateway, and then press
Enter. The cursor automatically appears at the first digit.
4 At each position of the gateway address, use the up and down arrows
to change the value of each digit. Press
Enter to advance the cursor to
the next digit.
When you have advanced through all of the digits of the gateway
address, the autoloader displays
Enter to save.
5 Press Enter. New Gateway is xxx.xxx.xxx appears on the LCD. You do
not need to reboot the autoloader.
6 Press
Escape or Enter to return to the Ethernet submenu.
System Time 5
The system time is displayed by On-board Remote Management and it is
used internally when logging events and errors. The system time is either
regular time or power-on time. Regular time is Month/Date/Year Time,
such as Nov/21/2004 19:28. Power-on time is Power On Cycles/Power
On Hours. For example,
POC: 00121, POH: 00002:07:45 where POC is the
number of times the system has booted since it was manufactured, and
POH is the number of hours, minutes, and seconds since the last system
boot. If regular time is known, it will be used, otherwise power-on time is
used.
Setting the Time Zone 5
To set the time zone:
1 From the main menu, scroll to
Configuration, and then press Enter.
2 From the
Configuration menu, scroll to Time, and then press Enter.
Note: If you make a mistake, press
Escape to backspace to the
digit you want to change.