User's Manual
Chapter 4 On-board Remote Management
Configurations Page
Quantum SuperLoader 3 User’s Guide 55
The element addresses vary depending on which magazine is configured.
If
Left or Right is selected, and both magazines are physically installed,
the front panel and On-board Remote Management allow the user access
to the other magazine, but the SCSI host will not have access.
To set the
Magazines option:
1 From any page, click the
Configurations heading. The Configurations
screen displays.
2 Scroll to
Magazines. The Magazines options display.
A check mark displays after the currently enabled mode.
3 Do one of the following:
• To leave the
Magazines mode unchanged, press Esc.
•To change the
Magazines configuration, scroll to the setting you
want for the autoloader, selecting the appropriate check box, and
then click
submit. These settings include Both, Right, and Left.
The message
This will require a power cycle and ISV configuration
change. Enter To Continue
is displayed.
• To continue with the change, press
submit. The message Please
power cycle the tape autoloader and reconfigure the ISV app.
displays.
Setting the System Time
4
The system time is displayed by On-board Remote Management and is
used internally for logging events and errors.
The time will be reset automatically if a time server is configured.
Otherwise, the time must be set through On-board Remote Management.
The time zone setting is not lost when powered off.
Note: If the time was set using On-board Remote Management,
whether connected to a time server or not, the autoloader
automatically corrects for daylight savings time. If the time
does not properly correct for daylight savings time, you must
correct for daylight savings time manually.