User's Manual
Bugcheck Error Logs (SDLT 600 only)
Quantum SuperLoader 3 User’s Guide 151
Table 18 Bugcheck Log Field
Descriptions
Field Description
Event Number: The Event Number is one of the common first line fields explained in the Event Types
sections. Below is a listing of the Bugchecks for each event number.
B810 Library Port Communications problems—Library or drive problem. If the problem
continues multiple times after you reset the drive, contact customer support.
E204 Unexpected Time 2 Interrupt—Drive problem. If the problem continues multiple times
after you reset the drive, contact customer support.
EE01 Spurious Non-Askable Interrupt—Drive problem. If the problem continues multiple
times after you reset the drive, contact customer support.
EE02 Spurious Time Interrupt—Drive problem. If the problem continues multiple times after
you reset the drive, contact customer support.
EE03 Spurious Level 5 Interrupt—Drive problem. If the problem continues multiple times
after you reset the drive, contact customer support.
EE04 Spurious Drive Comm Interrupt—Drive or Loader problem. If the problem continues
multiple times after you reset the drive, contact customer support.
EE06 Spurious Diagnostic Comm Interrupt—Drive problem. If the problem continues
multiple times after you reset the drive, contact customer support.
EE08 Watch Dog Timer Expired—SCSI bus, host controller, or drive problem. If the problem
continues multiple times after you reset the drive, contact customer support.
EE09 Spurious Power Fail—Power supply or power cables problem. If the problem continues
multiple times after you reset the drive, contact customer support.
EE0D Spurious Level 6 Interrupt—Drive problem. If the problem continues multiple times
after you reset the drive, contact customer support.
F202 Loader Time-Out—Loader problem. If the problem continues multiple times after you
reset the drive, contact customer support.