User's Manual

Chapter 6 Diagnostics
On-board Remote Management Diagnostic Tests
Quantum SuperLoader 3 User’s Guide 87
4 If the test is successful, press Enter to return to the Diagnostics test
menu. For detailed results of a test, use On-board Remote
Management to retrieve the diagnostic test status (see Diagnostics
Using On-board Remote Management).
On-board Remote Management Diagnostic Tests
You can perform the following diagnostic tests from On-board Remote
Management:
•LoaderPicker Test
Loader—Magazine Test
Loader—Inventory Test
Random Moves
Diagnostics Using On-
board Remote
Management 6
To perform diagnostic tests using On-board Remote Management:
1 Open a Web browser and connect to the autoloader. The On-board
Remote Management main menu displays.
2 Click the
Diagnostics heading. A login window displays.
3 Type an
Administrator user name and a password, and then click
Enter. The Diagnostics submenu displays.
4 Select the test you wish to perform from the
Diagnostics drop-down
menu, and then click
Start Test.
The selected diagnostic test runs. While the test is running, you can
view the status of the test. To view the status, from
View Diagnostic
Test Progress
, click View Status.
Note: On-board Remote Management allows you to request all
diagnostic tests, but any tests that require a cartridge to be
inserted will time out unless someone manually inserts the
cartridge at the appropriate time.