User's Guide
Table Of Contents
- Preface
- Theory of Operation
- Media Changer Commands
- Overview of Command and Status Processing
- Media Changer Command Descriptions
- Initialize Element Status Command (07h)
- Inquiry Command (12h)
- Load Unload Command (1Bh)
- Log Sense Command (4Dh)
- Mode Select (6) / (10) Command (15h / 55h)
- Mode Sense (6) / (10) Command (1Ah/ 5Ah)
- Move Medium Command (A5h)
- Persistent Reserve In Command (5Eh)
- Persistent Reserve Out Command (5Fh)
- Position to Element Command (2Bh)
- Prevent/Allow Medium Removal (1Eh)
- Read Buffer Command (3Ch)
- Read Element Status Command (B8h)
- Release Element (10) Command (57h)
- Release Unit (6) Command (17h)
- Report Device Identifier Command (A3h)
- Report LUNS Command (A0h)
- Request Sense Command (03h)
- Reserve Element (10) Command (56h)
- Reserve Element (6) Command (16h)
- Send Diagnostic Command (1Dh)
- Set Device Identifier Command (A4h)
- Test Unit Ready Command (00h)
- Write Buffer Command (3Bh)
- Index

Chapter 2 Media Changer Commands
Log Sense Command (4Dh)
Quantum SuperLoader 3 Software Interface Guide 40
Table 18 Device Status Log
Sense (0001h)
Field Name Description
Temperature These two bits indicate the temperature of the device. This field follows the
following format:
Bit 3 Bit 2 Description
0 0 Not supported
01OK
1 0 Warning: Safe temperature exceeded.
1 1 Maximum temperature exceeded.
Status These two bits indicate the overall condition of the device. The status of the
device follows the following format:
Bit 1 Bit 0 Description
0 0 Not supported
01OK
10Degraded
1 1 Failed