User's Guide
Table Of Contents
- Preface
- Theory of Operation
- Media Changer Commands
- Overview of Command and Status Processing
- Media Changer Command Descriptions
- Initialize Element Status Command (07h)
- Inquiry Command (12h)
- Load Unload Command (1Bh)
- Log Sense Command (4Dh)
- Mode Select (6) / (10) Command (15h / 55h)
- Mode Sense (6) / (10) Command (1Ah/ 5Ah)
- Move Medium Command (A5h)
- Persistent Reserve In Command (5Eh)
- Persistent Reserve Out Command (5Fh)
- Position to Element Command (2Bh)
- Prevent/Allow Medium Removal (1Eh)
- Read Buffer Command (3Ch)
- Read Element Status Command (B8h)
- Release Element (10) Command (57h)
- Release Unit (6) Command (17h)
- Report Device Identifier Command (A3h)
- Report LUNS Command (A0h)
- Request Sense Command (03h)
- Reserve Element (10) Command (56h)
- Reserve Element (6) Command (16h)
- Send Diagnostic Command (1Dh)
- Set Device Identifier Command (A4h)
- Test Unit Ready Command (00h)
- Write Buffer Command (3Bh)
- Index

Chapter 2 Media Changer Commands
Log Sense Command (4Dh)
Quantum SuperLoader 3 Software Interface Guide 38
Table 16 Device Status Log
Sense Header
Figure 23 Parameters for
Device Status Log Sense Page
Field Name Description
Page Code The Page Code echoes the page code that was
specified in the
LOG SENSE command descriptor
block.
Page Length The Page Length field specifies the number of bytes
available and depends on the parameters requested.
Bit
Byte76543210
0 - 1
Parameter Code
2
DU DS TSD ETC TMC Rsv’d LP
3
Parameter Length (04h)
4 - 7
(MSB)
Parameter Value
(LSB)