User's Guide
Table Of Contents
- Preface
- Theory of Operation
- Media Changer Commands
- Overview of Command and Status Processing
- Media Changer Command Descriptions
- Initialize Element Status Command (07h)
- Inquiry Command (12h)
- Load Unload Command (1Bh)
- Log Sense Command (4Dh)
- Mode Select (6) / (10) Command (15h / 55h)
- Mode Sense (6) / (10) Command (1Ah/ 5Ah)
- Move Medium Command (A5h)
- Persistent Reserve In Command (5Eh)
- Persistent Reserve Out Command (5Fh)
- Position to Element Command (2Bh)
- Prevent/Allow Medium Removal (1Eh)
- Read Buffer Command (3Ch)
- Read Element Status Command (B8h)
- Release Element (10) Command (57h)
- Release Unit (6) Command (17h)
- Report Device Identifier Command (A3h)
- Report LUNS Command (A0h)
- Request Sense Command (03h)
- Reserve Element (10) Command (56h)
- Reserve Element (6) Command (16h)
- Send Diagnostic Command (1Dh)
- Set Device Identifier Command (A4h)
- Test Unit Ready Command (00h)
- Write Buffer Command (3Bh)
- Index

Chapter 1 Theory of Operation
Events
Quantum SuperLoader 3 Software Interface Guide 4
• If initialization is successful, it generates a not-ready to ready
transition (
SK=6 ASC=28 ASCQ=00), otherwise, failure sense data is
set accordingly.
SuperLoader 3 Offline 1
When a user accesses the SuperLoader 3 via the front panel or On-board
Remote Management in such a way that would cause conflict with a SCSI
command, the SuperLoader 3 is put into an off-line state. If a SCSI
command is received while in this off-line state, a not ready check
condition is reported (
SK=02 ASC=04 ASCQ=07).
Magazine Insertion/
Removal 1
The SuperLoader 3 must be powered-on with at least one magazine,
otherwise a check condition is reported (
SK=02 ASC=04 ASCQ=03).
While the system is on-line, the user may remove a magazine blank and
replace it with a magazine. The SuperLoader 3 will calibrate the newly
installed magazine and check the presence of tape cartridges in each of
the storage elements. While this inventory is in progress, the
SuperLoader 3 will report a not-ready check condition (
SK=02 ASC=04
ASCQ=01
). Once the inventory is complete, the SuperLoader 3 reports a
unit attention (
SK=06 ASC=3B ASCQ=13).
Similarly, while a magazine is in the process of being removed, a
not-ready check condition is reported (
SK=02 ASC=04 ASCQ=07). Once the
operation is complete, by replacing the magazine with a blank a unit
attention is reported (
SK=06 ASC=3B ASCQ=12).
While one or both of the magazine bays are open, a not ready check
condition is reported (
SK=02 ASC=04 ASCQ=03).
Maximum Temperature
Exceeded 1
The SuperLoader 3 monitors the ambient temperature within the system.
If the temperature exceeds the maximum safe temperature for the media,
the SuperLoader 3 will disable all movement until the temperature
decreases below a safe threshold. While the temperature remains
excessive, SCSI commands that require movement will fail (
SK=04
ASC=0B ASCQ=01
).