User's Guide
Table Of Contents
- Preface
- Theory of Operation
- Media Changer Commands
- Overview of Command and Status Processing
- Media Changer Command Descriptions
- Initialize Element Status Command (07h)
- Inquiry Command (12h)
- Load Unload Command (1Bh)
- Log Sense Command (4Dh)
- Mode Select (6) / (10) Command (15h / 55h)
- Mode Sense (6) / (10) Command (1Ah/ 5Ah)
- Move Medium Command (A5h)
- Persistent Reserve In Command (5Eh)
- Persistent Reserve Out Command (5Fh)
- Position to Element Command (2Bh)
- Prevent/Allow Medium Removal (1Eh)
- Read Buffer Command (3Ch)
- Read Element Status Command (B8h)
- Release Element (10) Command (57h)
- Release Unit (6) Command (17h)
- Report Device Identifier Command (A3h)
- Report LUNS Command (A0h)
- Request Sense Command (03h)
- Reserve Element (10) Command (56h)
- Reserve Element (6) Command (16h)
- Send Diagnostic Command (1Dh)
- Set Device Identifier Command (A4h)
- Test Unit Ready Command (00h)
- Write Buffer Command (3Bh)
- Index

Chapter 2 Media Changer Commands
Request Sense Command (03h)
Quantum SuperLoader 3 Software Interface Guide 127
04 07 Unit Not Ready, Operation in Progress
44 00 Internal Target Failure
04h
HARDWARE
ERROR
08 00 LUN Communication Failure
08 01 LUN Communication Timeout Failure
0B 01 Over Temperature Condition Error
15 01 Mechanical Positioning Error
40 83 Diagnostic Failure
40 84 POST Soft Error
53 00 Media Load Failure
53 01 Media Unload Failure
05h
ILLEGAL
REQUEST
1A 00 Parameter List Length Error
20 00 Illegal Opcode
21 01 Invalid Element Address
24 00 Invalid CDB Field
24 86 Invalid Offset
24 87 Invalid Size
24 89 Image Data Over Limit
24 8B Image/Personality is Bad
24 8C Not Immediate Command during Code Update
24 91 Bad Autoloader Image EDC
25 00 Illegal LUN
26 00 Parameter List Error, Invalid Field
Sense Key ASC ASCQ Description