User's Guide
Table Of Contents
- SCSI Command Support
- SCSI Commands
- Initialize Element Status - 07h
- Initialize Element Status With Range - E7h
- Inquiry - 12h
- Log Sense - 4Dh
- Mode Select (6) - 15h
- Mode Select (10) - 55h
- Mode Sense (6) - 1Ah
- Mode Sense (10) - 5Ah
- Mode Pages
- Move Medium – A5h
- Persistent Reserve In – 5Eh
- Persistent Reserve Out – 5Fh
- Position to Element – 2Bh
- Prevent Allow Medium Removal – 1Eh
- Read Buffer – 3Ch
- Read Element Status – B8h
- Release Element (6) – 17h
- Release Element (10) – 57h
- Report LUNS – A0h
- Request Sense – 03h
- Request Volume Element Address - B5h
- Reserve Element (6) - 16h
- Reserve Element (10) - 56h
- Send Diagnostic - 1Dh
- Send Volume Tag - B6h
- Test Unit Ready (00h)
- Write Buffer (3Bh)

Quantum Scalar Intelligent Libraries SCSI Reference Guide Guide 81
04h 03h x The library is not ready and a manual intervention is required
04h 12h x Logical unit not ready, offline
04h 83h x The library is not ready due to aisle power being disabled
04h 8Dh x The library is not ready because it is offline
08h 00h x LU Communication Failure
08h 01h x
LU Communication – Timeout
08h 80h x LU Communication – SCSI Failure
08h 82h x LU Communication – SCSI Command Execution or Queuing
Failure
08h 83h x LU Communication – SCSI Command Failed
08h 84h x LU Communication – SCSI Time-Out
08h 85h x LU Communication – SCSI Autosense Failed
08h 86h x LU Communication – SCSI Aborted
08h 87h x LU Communication – SCSI Abort Failed
08h 88h x LU Communication – SCSI Status Failed
08h B0h x LU Communication – FC Data Underrun
08h B1h x LU Communication – FC DMA Error
08h B2h x LU Communication – FC Reset
08h B3h x LU Communication – FC Data Overrun
08h B4h x LU Communication – FC Queue Full
08h B5h x LU Communication – Port Unavailable
08h B6h x LU Communication - Port Logged Out
08h B7h x LU Communication - Port Configuration Changed
15h 01h x A mechanical positioning error occurred
1Ah 00h x Parameter list length error
1Bh 00h x Synchronous data transfer error
20h 00h x Illegal opcode in CDB
21h 01h x Invalid element address in CDB
24h 00h x Invalid field in CDB
25h 00h x Illegal LUN
26h 00h x Invalid field in Parameter List
Table 79 Additional Sense Codes and Qualifiers (Continued)
ASC ASCQ
Sense Keys
Description
2456B