Release Notes

Known Issues
Scalar i500 Library Release Notes 8
KnownIssues
ThisreleaseofScalari500Libraryi8.3(660.GS007),firmwarehasthefollowingknownissues.
Change
Request
Number
Service
Request
Number
Description Workaround
22967 Whenupgradingalibrarywitha
Model2robottofirmwareversion
570G,thelibrarymaygenerate
RASticketT124 - Robotics
Hardware Error - RCB.
Explanation:Theproblemhasbeen
fixedincodeversions570Gandlater,
butbecausetheproblemresidesin
previouscodeversions,youmay
encounterthisissuewhenupgrading
fromapreviousversiontoversion570G.
Workaround:Leavethelibrarypowered
onfor20minutesaftertheticketwas
postedtoallowthepickertorecover.If
youopenalibrarydoororpowercycle
thelibraryduringthistime,thepicker
maybecomeinoperableandrequire
replacement.
25651 Ifatapedrivefirmwareupdatefails
whenusingafirmwareupdate
methodotherthanautoleveling,
thelibrarymayincorrectly
generateRASticketT112 -
Invalid Tape Drive Firmware
Imageinadditiontocorrectly
generatingRASticketT109 -
Tape Drive Firmware Update
Failure.
IgnoreT112,andfollowtheresolution
stepsforT109.
25964 SR1070246 Ifalibraryisupgradedandfailsto
initializeuponreboot,thesnapshot
namewillbeincorrect.
Snapshotinformationiscorrectother
thanthename.Correctthehardware
issuethatiscausinglibrarynotto
initialize.
27092 OccasionallytheFCI/Oblade
serialnumberisreported
incorrectlyontheTools-FCI/O
BladeInformationscreen(Tools >
FC I/O Blade Info).
Iftheserialnumberendswithinvalid
characters,ignoretheinvalid
characters.Therestoftheserialnumber
iscorrect.