Chapter 12 Installing, Removing, and Replacing
Cabling the Library
Scalar i500 User’s Guide 298
b If you need to add expansion modules to the control module,
remove the module terminator from the control module
terminator connection that is closest to the expansion module.
c Replace the module terminator in the expansion module in the
terminator connection that is furthest from the control module.
4 Connect the module-to-module cable from the control module to the
expansion module.
5 Connect your Ethernet cable to the Gigabit (GB) Ethernet port on the
library control blade (LCB) for remote access to the library via the
Web client.
6 Connect a power cord to the outlet on the power supply on the rear of
the library.
There should always be a power cord connected to the power supply
on the control module. If redundant power supplies are used,
connect a power cord to each of the additional power supply outlets.
7 Power on the library.
a Turn on the rear power switch of each of the power supplies.
b Turn on the front power button.
c Power up the host system.
8 Verify communication with all devices on the bus.
9 Configure the library using the commands on the operator panel. See
configuration information in Configuring Your Library
on page 52.
Cabling Libraries With
SAS Tape Drives 12
Each SAS tape drive should be connected directly to the host bus adapter
(HBA) using one SAS cable. The LTO-4 and LTO-5 SAS tape drives in the
Scalar i500 library use the SFF-8088 type SAS connector. The connector
needed on the host end of the cable depends on the type of Host Bus
Adapter (HBA) being used.