User's Guide

Chapter 6 Storage Networking
Configuring Data Path Failover
Scalar i500 User’s Guide 155
Details about data path failover include:
The tape drives must be HP LTO-5 Fibre Channel tape drives.
HP LTO-5 FC tape drive firmware must be at the version qualified
with the Scalar i500 library (see the Scalar i500 Release Notes for
qualified firmware levels).
The library must have a Storage Networking license sufficient to
cover the tape drive(s) on which you want to configure data path
failover.
Both FC ports on the tape drive must be connected to a host or
switch. Neither tape drive port may be connected to a Fibre Channel
I/O blade.
Data path failover must be enabled on the tape drives (data path
failover is disabled by default).
Tape drive topology settings must be set to Point to Point.
Enabling Data Path
Failover 6
To enable data path failover:
1 Connect both tape drive Fibre Channel ports (Port 1 and Port 2) to a
host or switch (see Figure 21
).
Note: If you are NOT using data path failover on a tape drive, then
only Port 1 is used for data path or control path transmission.
The library and host will not recognize Port 2 unless data path
failover is enabled on the tape drive.