User's Manual
Chapter 2: Initial Installation and Setup
Turning the Library ON and Configuring Network Settings
24 Quantum Scalar i40 and Scalar i80 User’s Guide
Figure 15 Setup Wizard –
Current Configuration Screen
Do one of the following:
• To accept the current settings, press Accept.
•
To change any of the settings, press Change. Th
is will delete the
current partitions, and you are asked to confirm you want to do
this. If you agree, the library deletes the partitions, which take
about 30 seconds. When the partitions are deleted, you are
guided through several more screens to change the number of
partitions, I/E station slots, and cleaning slots. Use the
directional buttons as described in Step
5 on page 21 and press
Accept when comp
lete.
• Partitions — The minimum number of partitions you can
create
is one. The maximum is equal to the number of tape
drives installed in the library. The library assigns resources
proportionately among the partitions. You can change
resource allocation later via the Web client. For details, see
Working With Partitions on page 52.
• I/E Station Slots — You can create a maximum of five I/E
station sl
ots on a Scalar i40 and a maximum of ten on a
Scalar i80. The mini
mum is zero. Be aware that if you
config
ure zero I/E station slots, you will not be able to
import and export tape cartridges.
• Cleaning Slots — You can configure a minimum of zero and
a maximu
m of four cleaning slots.