User`s guide

Chapter 10: Working With Cartridges and Barcodes
Barcode Requirements
266 Quantum Scalar i40 and Scalar i80 User’s Guide
included, the label must have a five to 13 character barcode
followed by a media ID, for example, “XXXXXXXXXXXXXL2”. If a
media ID is not included, the label must have a five to 15 character
barcode, for example, “XXXXXXXXXXXXXXX”.
Media ID Last — Five to 13 character barcode number followed by
media ID, for example, “XXXXXXXXXXXXXLT”. The media ID is
reported to the host last.
Media ID First Five to 13 character barcode number preceded by
media ID, for example, “L4XXXXXXXXXXXXX”. The media ID is
reported to the host first.
Standard — (default) Five to 15 characters total, including a
barcode number and optional media ID. The media ID is not
reported to the host. If a media ID is included, the label must have a
five to 13 character barcode followed by a media ID, for example,
“XXXXXXXXXXXXXL3”. If a media ID is not included, the label must
have a five to 15 character barcode, for example,
“XXXXXXXXXXXXXXX”.
Quantum-supplied barcode labels provide the best results. Barcode
labels from other sources can be used, but they must meet the
following requirements:
ANSI MH10.8M-1983 Standard
Number of digits: 5 to 15 (default for LTO is 6+2)
Background reflection: greater than 25 percent
Print contrast: greater than 75 percent
Ratio: greater than 2.2
Module: minimum .254 mm (10 mil)
Print tolerance: ± 57 mm
Additional Requirements:
Length of the rest zones: 5.25 mm ± 0.25 mm
No black marks should be present in the intermediate spaces or rest
zones
No white areas should be present on the bars