User's Guide
Appendix A: MIBs Implemented
Downloading the SNMP MIB from the Library
Scalar i40 and Scalar i80 Basic SNMP Reference Guide 21
 SYNTAX INTEGER { good(1), failed(2), degraded(3), warning(4), 
informational(5), unknown(6), invalid(7)}
 CleaningStatus ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION "Device cleaning status."
 SYNTAX INTEGER { recommended(1), notNeeded(2), required(3) }
--
-- Overall Tape Library parameters
-- 
 libraryIpAddress OBJECT-TYPE
 SYNTAX DisplayString
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION "The IP address of this SNMP agent. If the 
 library has only an IPV4 address, or both an
 IPV4 and an IPV6 address, then the IP address is
 displayed in IPV4 format (xxx.xxx.xxx.xxx). If
 the library only has an IPV6 address, then it
 will report an IPV6 address."
 ::= { smallTapeLibrarySystem 1 }
 librarySNMPAgentDescription OBJECT-TYPE
 SYNTAX DisplayString
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION "Description of the library SNMP agent."
 ::= { smallTapeLibrarySystem 2 }