User`s guide
Chapter 6 Maintaining Your Library
Maintenance Actions
Scalar i6000 User’s Guide 431
• Full system tests or individual field replaceable unit (FRU) tests
• Logs of installation and configuration tests
• Graphical reports showing passed, marginal, and failed results
• No affect to integrity of data
To perform these tests, the accessor assembly must be ready and
fu
nctional, and the library must be powered on. In addition, the library
must be in an offline state, and at least one scratch tape must be inserted
in the I/E station.
Test Descriptions
6
This section describes the verification tests that are available.
Installation Verification Test
6
The installation verification test enables
you to verify that the library’s
installation and configuration is complete and functioning correctly. The
installation verification test runs the following individual tests:
• Library alignment test
• Picker assembly test
• I/E station assembly test
•Get/Put test
• Scanner fiducial test
The smaller library configuration will require about 1 hour and the larger
configurations will re
quire as long as 6 hours to run the installation
verification test. The time to complete individual tests on an eight-frame
configuration is approximately:
• Library alignment test - 30 minutes
• Picker assembly test - 1 minute
• I/E station assembly test - 5 minutes
for each 24 slot I/E station
• Get/Put test - 120 minutes
• Scanner fiducial test
- 75 minutes
These times do not include debug or repair time.
Note