User`s guide
Chapter 6 Maintaining Your Library
Maintenance Actions
Scalar i6000 User’s Guide 406
Updating Drive Firmware Using Update Tapes 6
It is important to verify that the library firmware version is compatible
with the new drive firmware version. To determine the appropriate drive
firmware, see the library’s Release Notes or contact Quantum technical
support. If you need to update drive firmware by using update tapes,
perform the following procedure.
If you are viewing a partition, drive firmware
update operations affect drives that are within the
partition only, and uses the I/E slots within the
partition. If you are viewing the physical library,
drive firmware update operations affect all drives.
1 Write down the Barcode number on the tape before inserting it into
the I/E Station.
2 Fr
om the 'Physical Library' view, insert the firmware tape(s) into any
I/E station slots in the library.
3 On the Update Drive Firmware dialog box, select FMR Tape.
Note
Note
If you are in the “Logical Library” view, insert the
firmware tape(s) into I/E slots belonging to the
partition of the current 'Logical Library' view.