User`s guide

Chapter 4 Configuring Your Library
Setting Up Policies for the Physical Library
Scalar i6000 User’s Guide 160
3 Click Setup Physical Library.
The Physi
cal Library dialog box appears.
4 Select Enable in the Automatic Teach area to schedule automatic
calibration and configuration of the robotic assembly when the
library powers up or when the library door is opened and closed.
Automatic Teach
is disabled by default.
5 Select
Enable in the Automatic Inventory area to schedule automatic
inventories of library contents when the library powers up or when
the library door is opened and closed.
Automatic Inventory
is disabled by default.
6 Select
Enable in the Automatic Drive Unload area to cause the
library to issue unload commands when host applications issue move
media commands to the library. If you set this to Disable, proper
library operation requires host applications to issue unload
commands to the drives.
Automatic Drive Unload is
enabled by default.