Known Issues 5
Known Issues
This release of Scalar i6000 firmware has the following known issues. This list
contains
cumulative
information for all previously released Scalar i2000/i6000
library versions.
Change
Request
Number
Service
Request
Number
Description Workaround
16990 Installing Q-EKM with IBM Java disables
functioning Sun Java plug-in and i2000
Remote Management Interface (RMI) does
not function after Q-EKM install.
Upgrade Q-EKM software to version
251Q.GC00400 or later.
18432 After library software upgrade, an error
message states cannot connect to server.
Ignore the error message. Connect
again and confirm software was
upgraded.
18471 The library SCSI port does not properly
terminate when the library is connected via
a string of drives.
Do not terminate a string of SCSI
drives at the MCB.
18643 When interrupting a move from the
cleaning tape back to the cleaning slot, the
library does not place media in cleaning
slot.
Manually remove the tape from the
picker.
18702 Cannot connect to a library with SSL
enabled at an HTTPS address.
No workaround. Using SSL causes
extreme performance degradation
and is not recommended.
21663 When initially enabling Host Port Failover
on a FC I/O blade, the user is presented
with 2 possible ports to set a the primary
port, port 1 and port 2. If the user selects
port 1and sets the new parameter
everything works as expected. If the user
selects port 2 during initial enable, and
sets the new parameter, the value is
rejected and the user gets an error
message stating that the “Primary port
must be online.”
For Host Port Failover on a FC I/O
blade, port 2 cannot be enabled as
the primary port without first
enabling port 1 as the primary port.
Set port 1 as primary, save the
configuration, and then set port 2 as
primary.
27400 User can set 7404 FC blade initiator port to
1 Gb/sec when attached to a drive that
supports 8 Gb/sec.
1 Gb/sec is not an acceptable setting
for higher speed drives; it is an
incompatible setting. Choose a
higher setting or do not connect
8
Gb/sec drives to an FC I/O blade
(recommended).