Release Notes

Release Notes
Document 5502252 Rev D
February 2011
Documentation 5
Documentation 0
Scalar 50 Documentation 0 The following documents are currently available for the Scalar 50 (V55).
81-81767 A01 Scalar 50 Quick Start Guide
81-81768 A01 Scalar 50 User’s Guide
81-81769 A01 Scalar 50 Tape Drive Installation Instructions
81-81770 A01 Scalar 50 Tape Drive Replacement Instructions
81-81771 A01 Scalar 50 Magazine Upgrade/Exchange Instructions
81-81772 A01 Scalar 50 Chassis Repacking Instructions
81-81793 A01 Scalar 50 Power Supply Upgrade Instructions
81-81359 A01 TC2201 User’s Guide
6311658 A01 SNMP Integration Guide
81-81289 A01 Software Interface Guide
PCR 19853 The drive firmware update through the
Remote Management Pages sometimes
fails.
Try the procedure again, if it still fails use the
primary port connection to update drive
firmware.
PCR 19997 During a I/E column port operation, if
Release Magazine is selected from OCP
and tapes are moved around, the library
can fail after the door closes and a re-
scan occurs.
If load ports are being accessed, do not attempt
to release the magazine. This will be corrected
in future releases of library firmware
PCR 20130 The User password is rejected if it
contains “_”.
Do not attempt to use “_” with a user password.
Instead, use another non-alphanumeric
character in its place. This will be corrected in
future releases of library firmware.
PCR 20354 A drive log download from a Quantum
LTO-3 HH tape drive can cause a brief
loss of communication to the remote
management pages. The library status
icon will change to
Communication
Down
.
This is only a temporary loss of communication
(30 seconds to 2 minutes). After that time, the
communication to the remote management
pages will return. This will be corrected in
future releases of library firmware.
Document Number Document Title
Change
Request
Number
Service
Request
Number
Description Workaround