Make certain a cleaning cartridge is installed in the fixed cartridge
slot. (If the fixed slot contains a data cartridge and you follow these
steps, you will have to manually eject the data cartridge from the
tape drive.)

If security has been enabled, disable it (see page 34).

Switch to LCD Interface mode (see page 46).

From the Main Menu, select Maintenance Menu. Then select Clean
Drives Menu. The following screen displays:

Select the tape drive you want to clean. Drive 1 is the tape drive
closest to the magazine; Drive 2 is the tape drive farthest from the
magazine. When you select a drive, the following activities occur:
S The CHM picks the cleaning cartridge from the fixed slot and
inserts it in the tape drive you specified.
S The tape drive automatically performs the cleaning process and
ejects the cartridge when the process is complete (in several
minutes).
S The CHM automatically picks the cartridge from the tape drive
and replaces it in the fixed cartridge slot.