User's Guide
&KDSWHU
6FDODU$,7
Make certain a cleaning cartridge is installed in the fixed cartridge
slot. (If the fixed slot contains a data cartridge and you follow these
steps, you will have to manually eject the data cartridge from the
tape drive.)
If security has been enabled, disable it (see page 34).
Switch to LCD Interface mode (see page 46).
From the Main Menu, select Maintenance Menu. Then select Clean
Drives Menu. The following screen displays:
Select the tape drive you want to clean. Drive 1 is the tape drive
closest to the magazine; Drive 2 is the tape drive farthest from the
magazine. When you select a drive, the following activities occur:
S The CHM picks the cleaning cartridge from the fixed slot and
inserts it in the tape drive you specified.
S The tape drive automatically performs the cleaning process and
ejects the cartridge when the process is complete (in several
minutes).
S The CHM automatically picks the cartridge from the tape drive
and replaces it in the fixed cartridge slot.
→
C l e a n D r i v e 1
C l e a n D r i v e 2
↓