User's Guide

&KDSWHU
 6FDODU$,7
5HVHWWLQJWKHOLEUDU\
If the library has encountered an error and is still not operating after you
have tried the corrective action for the error, you may need to reset the
library. A reset causes the library and the tape drives to perform their
power-on self tests. Unless configured otherwise, tape drives will rewind
the tape after a reset, but will not eject the data cartridge.
To reset the library, you can use one of the following methods:
S Press
>5HVHW@
on the operator panel, then press
>(QWHU@
at the
confirmation screen (or press
>(VFDSH@
to cancel).
S Perform a power-on reset by turning the library off, then back on.
S Perform a remote hardware reset by plugging a cable into the remote
reset port on the back of the library and press a reset button on the
cable (see Appendix A for specifications).
1RWH
The library, tape drives, or the entire SCSI bus can also be
automatically reset by the host.
When the library is reset, both the library and tape drives perform
power-on self-tests. Then the Main Screen appears on the LCD.
1RWH
If the library is performing a cartridge move operation when it
is reset, it completes the move operation before it performs the
power-on self-test.
&$87,21
%HIRUHUHVHWWLQJWKHOLEUDU\PDNHVXUHWKH
OLEUDU\RUWDSHGULYHVDUHQRWFRPPXQLFDWLQJ
DFURVVWKH6&6,EXV5HVHWWLQJWKHOLEUDU\DQG
WDSHGULYHVPD\GLVUXSWFRPPXQLFDWLRQVRQ
WKH6&6,EXV