User's Guide
&KDSWHU
6FDODU$,7
5HVHWWLQJWKHOLEUDU\
If the library has encountered an error and is still not operating after you
have tried the corrective action for the error, you may need to reset the
library. A reset causes the library and the tape drives to perform their
power-on self tests. Unless configured otherwise, tape drives will rewind
the tape after a reset, but will not eject the data cartridge.
To reset the library, you can use one of the following methods:
S Press
>5HVHW@
on the operator panel, then press
>(QWHU@
at the
confirmation screen (or press
>(VFDSH@
to cancel).
S Perform a power-on reset by turning the library off, then back on.
S Perform a remote hardware reset by plugging a cable into the remote
reset port on the back of the library and press a reset button on the
cable (see Appendix A for specifications).
1RWH
The library, tape drives, or the entire SCSI bus can also be
automatically reset by the host.
When the library is reset, both the library and tape drives perform
power-on self-tests. Then the Main Screen appears on the LCD.
1RWH
If the library is performing a cartridge move operation when it
is reset, it completes the move operation before it performs the
power-on self-test.
&$87,21
%HIRUHUHVHWWLQJWKHOLEUDU\PDNHVXUHWKH
OLEUDU\RUWDSHGULYHVDUHQRWFRPPXQLFDWLQJ
DFURVVWKH6&6,EXV5HVHWWLQJWKHOLEUDU\DQG
WDSHGULYHVPD\GLVUXSWFRPPXQLFDWLRQVRQ
WKH6&6,EXV